Browsing by Author "Stripeikis, Jorge"
Now showing 1 - 9 of 9
Results Per Page
Sort Options
artículo de publicación periódica.listelement.badge Abatement of 2,4-D by H2O2 solar photolysis and solar photo-Fenton-like process with minute Fe(III) concentrations(2018-11) Serra-Clusellas, Anna; De Angelis, Laura; Lin, Chung-Ho; Vo, Phuc; Bayati, Mohamed; Sumner, Lloyd; Lei, Zhentian; Amaral, Nathalia B.; Bertini, Liliana María; Mazza, José; Pizzio, Luis R.; Stripeikis, Jorge; Rengifo-Herrera, Julian A.; Fidalgo de Cortalezzi, María Marta"The Photo-Fenton-like (PF-like) process with minute Fe(III) concentrations and the Hydrogen Peroxide Photolysis (HPP), using Xe-lamp or solar light as sources of irradiation, were efficiently applied to eliminate the herbicide 2,4-D from water. PF-like experiments concerning ferric and H2O2 concentrations of 0.6 mg L 1 and 20 mg L 1 respectively, using Xenon lamps (Xe-lamps) as a source of irradiation and 2,4-D concentrations of 10 mg L 1 at pH 3.6, exhibited complete 2,4-D egradation and 77% dissolved organic carbon (DOC) removal after 30 min and 6 h of irradiation respectively whereas HPP (in absence of ferric ions) experiments showed a 2,4-D reduction and DOC removal of 90% and 7% respectively after 6 h of irradiation. At pH 7.0, HPP process achieved a 2,4-D abatement of approximately 75% and a DOC removal of 4% after 6 h. PF-like exhibited slightly improved 2,4-D and DOC removals (80% and 12% respectively) after the same irradiation time probably due to the low pH reduction (from 7.0 to 5.6). Several chlorinated-aromatic intermediates were identified by HPLC-MS. These by-products were efficiently removed by PF at pH 3.6, whereas at neutral PF-like and acid or neutral HPP, they were not efficiently degraded. With natural solar light irradiation, 10 and 1 mg L 1 of 2,4-D were abated using minor H2O2 concentrations (3, 6, 10 and 20 mg L 1 ) and iron at 0.6 mg L 1 in Milli-Q water. Similar results to Xe-lamp experiments were obtained, where solar UV-B þ A light H2O2 photolysis (HPSP) and solar photo-Fenton-like (SPF-like) played an important role and even at low H2O2 and ferric concentrations of 3 and 0.6 mg L 1 respectively, 2,4-D was efficiently removed at pH 3.6. Simulated surface water at pH 3.6 containing 1 mg L 1 2,4-D, 20 mg L 1 H2O2 and 0.6 mg L 1 Fe(III) under natural sunlight irradiation efficiently removed the herbicide and its main metabolite 2,4-DCP after 30 min of treatment while at neutral pH, 40% of herbicide degradation was achieved. In the case of very low iron concentrations (0.05 mg L 1) at acid pH, 150 min of solar treatment was required to remove 2,4-D."artículo de publicación periódica.listelement.badge Applying the monitoring breakdown structure model to trace metal content in edible biomonitors: an eight-year survey in the Beagle Channel (southern Patagonia)(2020-02) Conti, Marcelo Enrique; Tudino, Mabel Beatriz; Finoia, Maria Grazia; Simone, Cristina; Stripeikis, Jorge"The purpose of this paper is to investigate the trace metal content in edible biomonitors (i.e., mollusks) in the Beagle Channel (southern Patagonia) and to assess the human health risks associated with their consumption. Rationale: The monitoring breakdown structure (MBS) conceptual model was applied to four sampling campaigns (2005 → 2012) that collected 729 samples of Mytilus chilensis and Nacella magellanica. The composition of trace elements (Cd, Cr, Cu, Ni, Pb and Zn) in the mollusks was determined using graphite furnace (GFAAS) or flame atomic absorption spectrometry (FAAS). We compared the mean obtained values with the maximum levels (MLs) of each element established by international organizations. Then, based on semi-structured interviews, we calculated the estimated daily intake (EDI) of local residents and compared it with safety reference doses, i.e., the provisional tolerable daily intake (PTDI), provisional maximum tolerable daily intake (PMTDI), and tolerable daily intake (TDI), as well as the benchmark dose level lower confidence limit for Pb (BMDL01, a reference point (RP)/point of departure (POD). Moreover, to obtain information about the potential health risks of ingesting heavy metals (HMs) through mollusk consumption, we evaluated the target hazard quotient (THQ) and the hazard index (HI). Findings: For Cd and Pb, 65% and 40% of bivalves exceeded the MLs established by the Mercado Común del Sur (Mercosur), respectively. Except for Cd in N. magellanica (i.e., 1.20 μg/kg/bw/day), EDI values were clearly lower than the safety reference doses. For Cr, Cu, Ni, Pb and Zn, mussels were safe for consumption and did not raise concerns for public health. Likewise, THQ values were well below one for most of the studied metals, indicating that the exposed human population is assumed to be safe. Occasional high consumers of mollusks from the most contaminated sites may be at some health risk. Originality: The food production system and the environment are complex systems; this is crucial to understand when we consider ecosystems as a food source (i.e., marine ecosystems). Here we consider edible biomonitors, that are organisms that can have a dual function. They are food, and at the same time, if properly calibrated, they can act as indicators of environmental quality. This study is the first to investigate relevant essential and non-essential trace metal content in two edible mollusks from the Beagle Channel in a long-term survey (2005 → 2012). The information variety was high; approximately thirteen thousand determinations were conducted to support the risk assessment for mollusk consumption. Other aspects connected with the health risks and the uncertainty factors related to the presence of essential and non-essential minerals in edible mollusks as well as the use of the MBS are also discussed."artículo de publicación periódica.listelement.badge Composite materials based on hybrid mesoporous solids for flow through determination of ultratrace levels of Cd(II)(2018-07) Minaberry, Yanina Susana; Stripeikis, Jorge; Tudino, Mabel Beatriz"In this work we present a solid phase extraction (SPE) flow through system coupled to graphite furnace atomic absorption spectrometry (GFAAS) for the determination of Cd(II) at ultratrace levels. The flow system holds a minicolumn which was filled, one in turn, with three different lab made materials: a) mesoporous silica functionalized with 3-aminopropyl groups from 3-aminopropyl triethoxysilane (HMS); b) HMS with a resin, Amberlite IR120; c) HMS-Amberlite IR120 and polyvinyl alcohol (PVA). All the solids were characterized by FTIR and SEM. Batch experiments were performed in order to study the optimum adsorption pH, the adsorption kinetics and the maximum adsorption capacity.The materials were compared in terms of their aptitude for the pre-concentration of the analyte under dynamic conditions. Microvolumes of HCl were employed for the release of cadmium and its introduction into the electrothermal atomizer. The operational variables of the flow system were also tested and optimized. The comparison of the figures of merit revealed HMS-A-PVA as the best option from an analytical point of view: limit of detection= 4.7 ng L-1, limit of quantification= 16 ng L-1, RSD %= 4 (n =6, 100 ng L-1), linear range: from LOQ up to 200 ng L-1 and a lifetime over 600 cycles with no obstructions to the free movement of fluids, material bleeding or changes on the analytical sensitivity. The proposed method was shown to be tolerable to several ions typically present in natural waters and was successfully applied to determination of trace of Cd(II) in real samples. A full discussion of the main findings with emphasis on the interaction metal ion/fillings will be provided."artículo de publicación periódica.listelement.badge Glyphosate and AMPA removal from water by solar induced processes using low Fe(III) or Fe(II) concentrations(2019-11) Serra-Clusellas, Anna; De Angelis, Laura; Beltramo, Mercedes; Bava, Melina Ailén; de Frankenberg, María Josefina; Vigliarolo, Julián; Di Giovanni, Nicolás; Stripeikis, Jorge; Rengifo-Herrera, Julián A.; Fidalgo de Cortalezzi, María Marta"A solar photo-Fenton-like (SPF-like) process is explored for the removal of 1 mg L−1 glyphosate and its main degradation by-product, aminomethylphosphonic acid (AMPA), from Milli-Q water by means of low Fe(III) concentrations (0.6–2 mg L−1) at pH = 2.8 and variable H2O2 concentrations at the laboratory scale. The research is focused on glyphosate and AMPA oxidation, which present similar toxicity patterns. A 1 mg L−1 glyphosate solution requires 5–6 h of the SPF-like process to be degraded when a minute Fe(III) concentration (0.6 mg L−1) is used in acidic water. Glyphosate abatement time is diminished to 2 h when the Fe(III) concentration is increased to 2 mg L−1. At pH levels above 2.8, the herbicide is partially adsorbed onto the colloids of iron oxyIJhydroxide) compounds. AMPA requires a higher oxidative power than glyphosate to be degraded, and more than 6 h of solar treatment are needed, using 10 mg L−1 h−1 H2O2 and 2 mg L−1 Fe(III) at acidic pH. Solar photo-Fenton (SPF), using 4 mg L−1 Fe(II) and 10 mg L−1 h−1 H2O2 at pH = 2.8, must be applied to achieve practically total AMPA removal in 6 h of irradiation. SPF-like and SPF treatments led to 70% and 80% mineralization, respectively, under the best operational conditions. This work demonstrates that SPF-like and SPF at low Fe(III) or Fe(II) concentrations are effective treatments for the removal of glyphosate from water at acidic pH. Continuous addition of H2O2 is required for AMPA abatement."artículo de publicación periódica.listelement.badge Managing complexity of marine ecosystems: from the monitoring breakdown structure (MBS) to the baseline assessment. Trace metal concentrations in biomonitors of the Beagle Channel, Patagonia (2005–2012)(2019-09) Conti, Marcelo Enrique; Tudino, Mabel Beatriz; Finoia, Maria Grazia; Simone, Cristina; Stripeikis, Jorge"In this study we propose a conceptual framework, i.e. the Monitoring Breakdown Structure (MBS) as a tool for the management of marine ecosystems. The conceptual framework thinks through the complexity of marine ecosystems keeping into account the variety (space) and variability (time) dimensions. Consistently with the MBS we have built the control charts of trace metal concentrations of two selected biomonitors in the Beagle Channel (south Patagonia) (case study). Thus, we have tested the aptitude of two species of mollusks as biomonitors of heavy metal (HMs) pollution. The selected species were the limpet Nacella (P) magellanica and the bivalve Mytilus chilensis. Seven hundred eighty-five samples were collected along 170 km of the coastal area of the Beagle Channel (BC), (Tierra del Fuego, Argentina) in seven selected georeferenced locations and four sampling campaigns (2005, 2007, 2011, 2012). Cd, Cr, Cu, Ni, Pb and Zn determinations in seawater and mollusks by atomic absorption spectrometry (AAS) were carried out. The calculation of the respective concentration factors (CFs), i.e. their capacity as strong bioaccumulators, was also conducted. This is of relevance because it aims to use these data as a baseline reference for other geographical areas. Second, we have compared metal bioaccumulation differences among sites and the contamination trend by building, for the first time, the control charts of the baseline metal concentrations in the biomonitors. For these purposes, we applied probabilistic Johnson's method. Furthermore, the control charts (based on four years baseline data) allowed us to test the contamination trend by plotting data from 2012 vs 2011. Our results confirm N. magellanica as an extremely strong accumulator of Cd, and M chilensis strong bioaccumulator of Cd and Zn. Zn was the most abundant metal followed by Cu. Overall, regarding the contamination trend, based on thousands of determinations we observed that the six mean metal levels were quite constant over time. Moreover, metal distribution among sites turned out to be not univocal (no one site is more contaminated than the other sites). Thus, the expected hypothesis of Ushuaia Harbour as being the most contaminated site should be reconsidered. This reinforces the hypothesis of our data as baseline data (except for cadmium), that should be considered in management decisions about future environmental monitoring programs, i.e. preventing/managing marine accidents."artículo de publicación periódica.listelement.badge A novel combination of experimental design and artificial neural networks as an analytical tool for improving performance in thermospray flame furnace atomic absorption spectrometry(2016-02) Morzan, Ezequiel; Stripeikis, Jorge; Goicoechea, Héctor; Tudino, Mabel Beatriz"In this work, we present the combined effect of artificial neural networks (ANN) and experimental design as a suitable analytical tool for improving the performance of thermospray flame furnace atomic absorption spectrometry (TS-FFAAS) using Mg as leading case. To this end, mixtures of different amounts of methanol, ethanol, and i-propanol in water were assayed as carriers at different flow rates and different flame stoichiometries (air/acetylene ratios). Different levels of these variables determined the experimental domain, consisting in a cube which was divided into eight identical cubical regions that allowed increase in the number of available experimental points. A Box–Behnken design (BBD) was employed in each one of the regions. The name Multiple Box–Behnken design (MBBD) was given to this new approach. Then, the features of ANN were exploited to find the optimum conditions for conducting Mg determination by TS-FFAAS. The prediction capability of ANN was examined and compared to the least-squares (LS) fitting when applied to the response surface method (RSM). The suitability of the new approach and the implications on TS-FFAAS analytical performance are discussed."tesis de doctorado.listelement.badge Nuevos desarrollos en el modelado matemático del proceso continuo para la producción en masa de polímeros de estireno en presencia de elastómeros =(2022-07) Laganá, María Laura; Estenoz, Diana; Stripeikis, Jorge"El objetivo general de esta tesis es investigar aspectos aún no dilucidados en el área de la ingeniería del proceso de polimerización en masa de estireno (St) en presencia de elastómeros para la producción de Poliestireno de alto impacto (HIPS). La investigación se enfoca en el entendimiento y modelado matemático de los fenómenos fisicoquímicos involucrados, en el estudio y empleo de nuevas técnicas de modelado para la simulación de sistemas complejos, y en la optimización de los procesos. Se pretende lograr desarrollos que contribuyan a diseñar y operar los procesos industriales continuos con alto grado de comprensión, y optimizados desde el punto de vista de la productividad y de la calidad del producto final."artículo de publicación periódica.listelement.badge Performance of two Patagonian molluscs as trace metal biomonitors: the overlap bioaccumulation index (OBI) as an integrative tool for the management of marine ecosystems(2019-06) Conti, Marcelo Enrique; Tudino, Mabel Beatriz; Grazia Finoia, Maria; Simone, Cristina; Stripeikis, Jorge"In this study, we have investigated Cd, Cr, Cu, Ni, Pb and Zn in the biomonitors Mytilus chilensis and Nacella (P) magellanica sampled along seven selected sampling sites along 170 km of the coastal area of the Beagle Channel (Tierra del Fuego, Argentina) in four sampling campaigns: 2005, 2007, 2011 and 2012. The control charts were built by applying Johnson’s probabilistic method for the first time in this marine area. We determined the metal concentration overlap ranges in the selected biomonitors (as well as medians and distribution), and the overlap bioaccumulation index (OBI) with respect to the lowest (OBI-L1) and the highest (OBI-L) extreme values of the overlap metal concentration ranges. The OBI can be used as an integrative tool in the management of prevailing unpolluted/polluted marine coastal ecosystems. It consents to identify the most suitable organisms for managing several environmental conditions where an ecosystem quality control is needed. The OBI-L1 index can be employed as a preventive signal of alarm when the contamination process is in its early stages. For Cd, Ni, Cu and Cr, Nacella showed high OBI-L values that suggest its use as a biomonitor for mainly polluted marine ecosystems, in particular for Cd. Mytilus showed high Cd values for the OBI-L1 which means that this species is highly sensitive to a very low variation of the Cd levels in seawater. The OBI index enhances the observer’s information variety about the performance of the molluscs as metal biomonitors in marine ecosystems. Eventually, here we propose to conceptualize the wide set of biomonitoring knowledge endowment as an open and evolutionary endowment of information variety supporting the environmental management."artículo de publicación periódica.listelement.badge Selective determination of Cr (VI) by on-line solid phase extraction FI-SPE-FAAS using an ion exchanger resin as sorbent: an improvement treatment of the analytical signal(2017-01) Rossi, Ezequiel; Errea, María Inés; Fidalgo de Cortalezzi, María Marta; Stripeikis, Jorge"A flow injection (FI) technique based on an on-line solid phase extraction (SPE) coupled with flame atomic absorption spectroscopy (FAAS) to selectively quantify chromium (VI) in the presence of chromium (III) was developed. An anion exchanger was used as solid sorbent and the detection limit found was two order of magnitude lower than that expected quantifying by FAAS. Until now, quantitative determinations in FAAS were carried out by measuring the height of the peaks rather than their area. In our hands, the software was reconfigured and the area under the peaks could be measured. Considering area instead of height, the enhancement factor increases from 6.7 to 360 (approx. 54 times) giving a detection limit of 0.034 μg·L − 1 , lower than that obtained using much more expensive instruments such as electrothermal atomic absorption spectrometry (ETAAS) or inductively coupled plasma-atomic emission spectrometry (IPC-AES), greatly enhancing the potential of this methodology for future use in speciation studies. The operation conditions were: pH 3, sample loading 50 mL·min − 1 , elution flow rate 7.5 mL·min − 1 . The anion exchanger lifetime was over 100 adsorption/desorption cycles. Anions commonly present in natural aqueous systems did not interfere in the chromium retention. The accuracy was validated using a certified reference material (Fluka Analytical, QC3453)."