Browsing by Author "Baez, Eduardo"
Now showing 1 - 5 of 5
Results Per Page
Sort Options
ponencia en congreso.listelement.badge A chopped front-end system with common-mode feedback for real time ECG applications(2017) Gardella, Pablo; Villa Fernández, Emanuel; Baez, Eduardo; Cesaretti, Juan Manuel"A Front-End system composed of an instrumentation amplifier with common-mode feedback and a second-order sigma-delta analog to digital converter is proposed. Chopping techniques are used to remove offset and low frequency noise to guarantee a noise floor below the signal of interest. Measurements show that common-mode feedback adds 71 dB to the CMRR at 50 Hz and the input referred noise is 1.17 μVRMS over the frequency range of 0.1 Hz to 400 Hz."póster.listelement.badge Desarrollo de un circuito integrado para mediciones de electrocardiografía (ECG)(2016) Villa Fernández, Emanuel; Gardella, Pablo; Angélico Engelhardt, Mathias; Baez, Eduardo; Cesaretti, Juan Manuel"Diseño y fabricación de un sistema electrocardiógrafo en un proceso de 0,5 μm. El sistema está compuesto por un amplificador instrumental choppeado y con una realimentación del modo común a través del sujeto bajo medición, un ADC Σ∆ de segundo orden, etapas de procesamiento digital y una interfaz de comunicación."ponencia en congreso.listelement.badge Design of ESD protections for ECG applications(2020-02) Gardella, Pablo; Baez, Eduardo; Cesaretti, Juan Manuel"This paper presents the design of Electrostatic Discharge (ESD) protections for a remote Electroencephalograph (ECG). Design and layout guidelines are analyzed to improve the ESD robustness of a Grounded-Gate NMOS (GGNMOS) cell based on a single well CMOS-only process. Experimental validation is done by means of a Time Domain Reflectometry (TDR) technique known as Transmission Line Pulse (TLP) testing. The silicon implementation of the proposed design passes ±3700V in the Human-Body Model (HBM)."ponencia en congreso.listelement.badge Low noise front-end and ADC for real-time ECG System in CMOS process(2019-03-14) Gardella, Pablo; Villa Fernández, Emanuel; Baez, Eduardo; Biberidis, Nicolás; Cesaretti, Juan Manuel"This paper presents the design and experimental results of a digital acquisition system based on a chopper-stabilized Instrumentation Amplifier with Common-Mode feedback for CMRR enhancement. Chopping techniques are used to remove both offset and flicker noise, detrimental effects characteristic of pure CMOS processes. A second-order, discrete-time, single-bit Sigma-Delta ADC with CIFB structure is used to convert the signal into the digital domain where it can be processed in real time to diagnose and report urgencies. Measurements on a 0.6μm process have shown that the input CMRR is boosted by 71dB when the feedback is closed through the patient. The input referred integrated noise for the overall system within the ECG band frequencies of 0.1Hz to 400Hz (including the quantization noise) is 4.2μVP, below the recommended maximum detection error of 10.0μVP."póster.listelement.badge Microelectrónica aplicada a Real-Time ECG(2018) Villa Fernández, Emanuel; Gardella, Pablo; Biberidis, Nicolás; Baez, Eduardo; Cesaretti, Juan Manuel"El proyecto es un sistema microelectrónico de ECG en tiempo real y bajo costo implementado en un circuito integrado diseñado completamente en la universidad. Además de medir la actividad del corazón, con este sistema se puede determinar la presencia de arritmias u otras enfermedades cardíacas."