Artículo de Publicación Periódica: Automatic glucose control during meals and exercise in type 1 diabetes: proof-of-concept in silico tests using a switched LPV approach
Fecha
2021
Título de la revista
ISSN de la revista
Título del volumen
Editor
Resumen
"Keeping the blood glucose levels within the safe range during meals and exercise still represents a major hurdle not only for patients with type 1 diabetes (T1D), but also for Artificial Pancreas (AP) systems. One of the reasons a fully (autonomous) closed-loop solution has not been released onto the market yet is the slow action of current insulin analogs. To partially overcome this limitation, the authors have previously designed a switched control strategy equipped with an insulin-on-board (IOB) safety loop that mitigates meal-related glucose excursions without carbohydrate counting. In this paper, a similar strategy based on a Linear Parameter-Varying (LPV) control law has been adapted to safely handle also exercise challenges with minimum user intervention. In silico results using the UVA/Padova simulator evidence that the proposed closedloop scheme is feasible under moderate-intense exercise bouts by effectively and safely reducing the risk of hypoglycemia."
Descripción
Palabras clave
DIABETES, PANCREAS, ORGANOS ARTIFICIALES, CONTROL DE VARIACION LINEAL DE PARAMETROS, INSULINA, GLUCOSA